The SECO-LARM Surface-Mount Electric Rim Strike designed with the strength and durability for use with rim-type exit devices with a Pullman latch bolt 3/4 throw. The strike features 12/24 VDC operating voltage selectable fail-safe/fail-secure operation horizontal adjustment and a surface-mount metal housing eliminating the need for frame cutting during installation. UL 294 and 1034 Listed Tamper-resistant 12/24 VDC Operating voltage Non-polarized connection Horizontal adjustment Accommodates up to 3/4 Pullman latch Reversible non-handed design Stainless steel construction Surface-mount on metal or wood frames Works with standard rim-type exit devices including SECO-LARM SD-962AR-36A and SD-962AR-36G For Indoor Use Only Static strength 1500-lb 6673N Tested for 250000 cycles UL Tested Low current draw: 540mA@12VDC 270mA@ 24VDC Field-selectable for fail-safe or fail-secure operation Spacers included: 3x 1/32 0.9mm The SD-998C series is intended to be used with UL Listed Exit Hardware The SD-998C series shall not impair the intended operation of an emergency unit The SD-998C series shall not impair the operation of panic hardware mounted on the door Specifications Operating Voltage 12/24 VDC Current Draw 540mA@12VDC 270mA@24VDC Latch Throw 3/4 Static Strength 1500-lb 6673N Dynamic strength 70ft-lb 95J Endurance 250000 cycles UL Tested Level IV Destructive attack Level I Line security Level I Standby power Level I Operating Temperature 14120 F -1049 C Operating Humidity 085% Dimensions 9×1-3/4×3/4 229x45x19 mm Troubleshooting Electric strike does not activate Dismount the strike and check that the wiring connector is connected properly. Ensure the wiring connector is connected to a 12 or 24VDC source. Use a multimeter to test that the strike is receiving the proper voltage and amperage. If it is not it may be necessary to use heavier gauge wires or increase the output of the power supply. Make sure the activation device keypad or push-button switch is working properly. Door does not open when the electric strike is activated Check that the door latch is operating properly and replace if necessary. The position of the electric strike may need to be adjusted by moving it or adding washers or shims. Strike makes a buzzing sound Connect the strike to a DC power supply.
- Non-polarized connection Horizontal adjustment
- Accommodates up to 3/4″ Pullman latch Reversible non-handed design
- Works with standard rim-type exit devices including SECO-LARM SD-962AR-36A and SD-962AR-36G
- Stainless steel construction Surface-mount on metal or wood frames
- For Indoor Use Only Field-selectable for fail-safe or fail-secure operation